LAMA00POL Site Information Form (site log v2.0)
     International GNSS Service
     See Instructions at:
       https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt


0.   Form

     Prepared by (full name)  : lamk@uwm.edu.pl
     Date Prepared            : 2024-04-15
     Report Type              : UPDATE
     If Update:
      Previous Site Log       : lama00pol_20240109.log
      Modified/Added Sections : 4.5, 4.6, 8.1.3, 8.1.1, 8.1.2, 8.2.2, 8.2.1,
                              : 8.2.3, 8.3.3, 8.3.1, 8.3.2, 13


1.   Site Identification of the GNSS Monument

     Site Name                : LAMKOWKO
     Nine Character ID        : LAMA00POL
     Monument Inscription     : LAMA
     IERS DOMES Number        : 12209M001
     CDP Number               : (A4)
     Monument Description     : PILLAR/CONCRETE
       Height of the Monument : 1.5 m
       Monument Foundation    : CONCRETE BLOCK
       Foundation Depth       : 2.6 m
     Marker Description       : (CHISELLED CROSS/DIVOT/BRASS NAIL/etc)
     Date Installed           : 1992-03-31T00:00Z
     Geologic Characteristic  : SAND
       Bedrock Type           : SEDIMENTARY
       Bedrock Condition      : FRESH
       Fracture Spacing       : (0 cm/1-10 cm/11-50 cm/51-200 cm/over 200 cm)
       Fault zones nearby     : NO
         Distance/activity    : (multiple lines)
     Additional Information   : IGS'92 Fiducial Station
                              : CERGOP Station
                              : SAGET and EXTENDED SAGET geodynamic networks
                              : Station
                              : EUREF GPS mark No 302


2.   Site Location Information

     City or Town             : Olsztyn
     State or Province        : Warmia and Mazury
     Country or Region        : POL
     Tectonic Plate           : EURASIAN
     Approximate Position (ITRF)
       X coordinate (m)       : 3524523.000
       Y coordinate (m)       : 1329693.000
       Z coordinate (m)       : 5129846.000
       Latitude (N is +)      : +535332.64
       Longitude (E is +)     : +0204011.76
       Elevation (m,ellips.)  : 186.7
     Additional Information   : (multiple lines)


3.   GNSS Receiver Information

3.1  Receiver Type            : ROGUE SNR-8000
     Satellite System         : GPS
     Serial Number            : T-228
     Firmware Version         : TURBOROGUE
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 1994-12-01T00:00Z
     Date Removed             : 1996-02-25T00:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : Damaged on 25-FEB-1996

3.2  Receiver Type            : ASHTECH Z-XII3
     Satellite System         : GPS
     Serial Number            : 209
     Firmware Version         : ASHTECH 1E82
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 1996-04-17T00:00Z
     Date Removed             : 1996-07-22T00:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.3  Receiver Type            : ROGUE SNR-8000
     Satellite System         : GPS
     Serial Number            : T-228
     Firmware Version         : TURBOROGUE
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 1996-07-23T00:00Z
     Date Removed             : 1998-04-25T00:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : Damaged on 25-APR-1998

3.4  Receiver Type            : ASHTECH Z-XII3
     Satellite System         : GPS
     Serial Number            : 1217
     Firmware Version         : 1G00
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 1998-04-26T00:00Z
     Date Removed             : 1998-05-01T00:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.5  Receiver Type            : ASHTECH Z-XII3
     Satellite System         : GPS
     Serial Number            : 209
     Firmware Version         : 1E82
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 1998-05-02T00:00Z
     Date Removed             : 1999-07-18T00:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : Firmware update

3.6  Receiver Type            : ASHTECH Z-XII3
     Satellite System         : GPS
     Serial Number            : 209
     Firmware Version         : CC00
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 1999-07-19T00:00Z
     Date Removed             : 2007-11-17T19:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.7  Receiver Type            : LEICA GRX1200GGPRO
     Satellite System         : GPS+GLO
     Serial Number            : 351072
     Firmware Version         : 4.10/3.012
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2007-11-17T19:00Z
     Date Removed             : 2008-02-16T08:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.8  Receiver Type            : LEICA GRX1200GGPRO
     Satellite System         : GPS+GLO
     Serial Number            : 351072
     Firmware Version         : 5.62/3.014
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2008-02-16T08:00Z
     Date Removed             : 2008-07-28T11:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.9  Receiver Type            : LEICA GRX1200GGPRO
     Satellite System         : GPS+GLO
     Serial Number            : 351072
     Firmware Version         : 6.00/3.015
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2008-07-28T11:00Z
     Date Removed             : 2009-03-19T10:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.10 Receiver Type            : LEICA GRX1200GGPRO
     Satellite System         : GPS+GLO
     Serial Number            : 351072
     Firmware Version         : 7.01/3.016
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2009-03-19T10:00Z
     Date Removed             : 2009-04-21T17:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.11 Receiver Type            : LEICA GRX1200GGPRO
     Satellite System         : GPS+GLO
     Serial Number            : 351072
     Firmware Version         : 7.02/3.017
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2009-04-21T17:00Z
     Date Removed             : 2010-05-04T06:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.12 Receiver Type            : LEICA GRX1200GGPRO
     Satellite System         : GPS+GLO
     Serial Number            : 351072
     Firmware Version         : 7.80/3.019
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2010-05-04T06:00Z
     Date Removed             : 2011-02-02T06:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.13 Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 351072
     Firmware Version         : 8.10/4.007
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2011-02-09T08:30Z
     Date Removed             : 2018-08-05T09:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.14 Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 351072
     Firmware Version         : 9.20/6.112
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2018-08-17T14:00Z
     Date Removed             : 2022-02-17T13:00Z
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.15 Receiver Type            : LEICA GR50
     Satellite System         : GPS+GLO+GAL+BDS+QZSS+SBAS
     Serial Number            : 1870222
     Firmware Version         : 4.50/7.710
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2022-02-17T13:00Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Temperature Stabiliz.    : (deg C) +/- (deg C)
     Additional Information   : (multiple lines)

3.x  Receiver Type            : (A20, from rcvr_ant.tab; see instructions)
     Satellite System         : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
     Serial Number            : (A20, but note the first A5 is used in SINEX)
     Firmware Version         : (A11)
     Elevation Cutoff Setting : (deg)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Temperature Stabiliz.    : (none or tolerance in degrees C)
     Additional Information   : (multiple lines)


4.   GNSS Antenna Information

4.1  Antenna Type             : AOAD/M_T        NONE
     Serial Number            : 263
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0610
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : NONE
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : 25 m
     Date Installed           : 1994-12-01T00:00Z
     Date Removed             : 2000-10-06T00:00Z
     Additional Information   : Between 26-APR-1998 and 1-MAY-1998
                              : RINEX contained wrong info
                              : about antenna type

4.2  Antenna Type             : ASH700936F_C    SNOW
     Serial Number            : 155
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0610
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : SNOW
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : 25 m
     Date Installed           : 2000-10-06T00:00Z
     Date Removed             : 2007-11-17T19:00Z
     Additional Information   : Ashtech original radome

4.3  Antenna Type             : LEIAT504GG      LEIS
     Serial Number            : 200033
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0600
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : LEIS
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : 25 m
     Date Installed           : 2007-11-17T19:00Z
     Date Removed             : 2022-02-17T13:00Z
     Additional Information   : (multiple lines)

4.4  Antenna Type             : LEIAR20         LEIM
     Serial Number            : 794207
     Antenna Reference Point  : BAM
     Marker->ARP Up Ecc. (m)  :   0.0600
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : LEIM
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : 25 m
     Date Installed           : 2022-02-17T13:00Z
     Date Removed             : 2024-01-08T13:00Z
     Additional Information   : (multiple lines)

4.5  Antenna Type             : LEIAT504GG      LEIS
     Serial Number            : 200033
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.0600
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : LEIS
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : 25 m
     Date Installed           : 2024-01-08T13:00Z
     Date Removed             : 2024-04-12T10:00Z
     Additional Information   : (multiple lines)

4.6  Antenna Type             : LEIAR20         LEIM
     Serial Number            : 25299035
     Antenna Reference Point  : BAM
     Marker->ARP Up Ecc. (m)  :   0.0600
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : LEIM
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : 24 m
     Date Installed           : 2024-04-12T10:00Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Additional Information   : (multiple lines)

4.x  Antenna Type             : (A20, from rcvr_ant.tab; see instructions)
     Serial Number            : (A*, but note the first A5 is used in SINEX)
     Antenna Reference Point  : (BPA/BCR/XXX from "antenna.gra"; see instr.)
     Marker->ARP Up Ecc. (m)  : (F8.4)
     Marker->ARP North Ecc(m) : (F8.4)
     Marker->ARP East Ecc(m)  : (F8.4)
     Alignment from True N    : (deg; + is clockwise/east)
     Antenna Radome Type      : (A4 from rcvr_ant.tab; see instructions)
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : (m)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


5.   Surveyed Local Ties

5.1  Tied Marker Name         : LAM1
     Tied Marker Usage        : CONTROL
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : 52.690 m
       dy (m)                 : 12.389 m
       dz (m)                 : -39.669 m
     Accuracy (mm)            : 1 mm
     Survey method            : GPS CAMPAIGN/TRIANGULATION
     Date Measured            : 1993-07-16T00:00Z
     Additional Information   : (multiple lines)

5.2  Tied Marker Name         : LAM2
     Tied Marker Usage        : CONTROL
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : -50.294 m
       dy (m)                 : -35.054 m
       dz (m)                 : 43.871 m
     Accuracy (mm)            : 1 mm
     Survey method            : GPS CAMPAIGN/TRIANGULATION
     Date Measured            : 1993-07-16T00:00Z
     Additional Information   : (multiple lines)

5.3  Tied Marker Name         : LAM3
     Tied Marker Usage        : CONTROL
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : -45.829 m
       dy (m)                 : 39.580 m
       dz (m)                 : 18.508 m
     Accuracy (mm)            : 1 mm
     Survey method            : GPS CAMPAIGN/TRIANGULATION
     Date Measured            : 1993-07-16T00:00Z
     Additional Information   : (multiple lines)

5.4  Tied Marker Name         : LAM5
     Tied Marker Usage        : CONTROL, DGPS ref. station
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : 98.290 m
       dy (m)                 : 81.945 m
       dz (m)                 : -75.120 m
     Accuracy (mm)            : 1 mm
     Survey method            : GPS CAMPAIGN/TRIANGULATION
     Date Measured            : 2000-06-16T00:00Z
     Additional Information   : (multiple lines)

5.x  Tied Marker Name         : 
     Tied Marker Usage        : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : (m)
       dy (m)                 : (m)
       dz (m)                 : (m)
     Accuracy (mm)            : (mm)
     Survey method            : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
     Date Measured            : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


6.   Frequency Standard

6.1  Standard Type            : EXTERNAL RUBIDIUM
       Input Frequency        : 5.0 MHz
       Effective Dates        : 1996-07-23/1997-07-30
       Notes                  : (multiple lines)

6.2  Standard Type            : INTERNAL
       Input Frequency        : (if external)
       Effective Dates        : 1997-07-31/1998-06-11
       Notes                  : (multiple lines)

6.3  Standard Type            : EXTERNAL RUBIDIUM
       Input Frequency        : 5.0 MHz
       Effective Dates        : 1998-06-12/1999-05-02
       Notes                  : (multiple lines)

6.4  Standard Type            : INTERNAL
       Input Frequency        : (if external)
       Effective Dates        : 1999-05-03/2001-01-27
       Notes                  : (multiple lines)

6.5  Standard Type            : EXTERNAL RUBIDIUM
       Input Frequency        : 5.0 MHz
       Effective Dates        : 2001-01-28/2001-07-24
       Notes                  : (multiple lines)

6.6  Standard Type            : INTERNAL
       Input Frequency        : (if external)
       Effective Dates        : 2001-07-24/CCYY-MM-DD
       Notes                  : (multiple lines)

6.x  Standard Type            : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
       Input Frequency        : (if external)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


7.   Collocation Information

7.x  Instrumentation Type     : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
       Status                 : (PERMANENT/MOBILE)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


8.   Meteorological Instrumentation

8.1.1  Humidity Sensor Model  : LB-710 HB
       Manufacturer           : LAB EL, POLAND
       Serial Number          : 
       Data Sampling Interval :   600 sec
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : NATURAL
       Height Diff to Ant     : 0 m
       Calibration date       : 2001-05-20
       Effective Dates        : 2001-05-25/2007-11-17
       Notes                  : (multiple lines)

8.1.2  Humidity Sensor Model  : MET3A
       Manufacturer           : PAROSCIENTIFIC, INC
       Serial Number          : 102592
       Data Sampling Interval :   300 sec
       Accuracy (% rel h)     : 2 % rel h
       Aspiration             : FAN
       Height Diff to Ant     : 0 m
       Calibration date       : 2007-08-14
       Effective Dates        : 2007-11-17/2008-06-26
       Notes                  : (multiple lines)

8.1.3  Humidity Sensor Model  : MET4A
       Manufacturer           : PAROSCIENTIFIC, INC
       Serial Number          : 106565
       Data Sampling Interval :   300 sec
       Accuracy (% rel h)     : 2 % rel h
       Aspiration             : FAN
       Height Diff to Ant     : 0 m
       Calibration date       : 2008-06-20
       Effective Dates        : 2008-06-26/CCYY-MM-DD
       Notes                  : (multiple lines)

8.1.x  Humidity Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.2.1  Pressure Sensor Model  : LB-716
       Manufacturer           : LAB EL, POLAND
       Serial Number          : 
       Data Sampling Interval : 600 sec
       Accuracy               : 0.5 hPa
       Height Diff to Ant     : 0 m
       Calibration date       : 2001-05-20
       Effective Dates        : 2001-05-25/2007-11-17
       Notes                  : (multiple lines)

8.2.2  Pressure Sensor Model  : MET3A
       Manufacturer           : PAROSCIENTIFIC, INC
       Serial Number          : 102592
       Data Sampling Interval : 300 sec
       Accuracy               : 0.08 hPa
       Height Diff to Ant     : 0 m
       Calibration date       : 2007-08-14
       Effective Dates        : 2007-11-17/2008-06-26
       Notes                  : (multiple lines)

8.2.3  Pressure Sensor Model  : MET4A
       Manufacturer           : PAROSCIENTIFIC, INC
       Serial Number          : 106565
       Data Sampling Interval : 300 sec
       Accuracy               : 0.08 hPa
       Height Diff to Ant     : 0 m
       Calibration date       : 2008-06-20
       Effective Dates        : 2008-06-26/CCYY-MM-DD
       Notes                  : (multiple lines)

8.2.x  Pressure Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (hPa)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.3.1  Temp. Sensor Model     : LB-710 HB
       Manufacturer           : LAB EL, POLAND
       Serial Number          : 
       Data Sampling Interval : 600 sec
       Accuracy               : 0.1 deg C
       Aspiration             : NATURAL
       Height Diff to Ant     : 0 m
       Calibration date       : 2001-05-20
       Effective Dates        : 2001-05-25/2007-11-17
       Notes                  : (multiple lines)

8.3.2  Temp. Sensor Model     : MET3A
       Manufacturer           : PAROSCIENTIFIC, INC
       Serial Number          : 102592
       Data Sampling Interval : 300 sec
       Accuracy               : 0.1 deg C
       Aspiration             : FAN
       Height Diff to Ant     : 0 m
       Calibration date       : 2007-08-14
       Effective Dates        : 2007-11-17/2008-06-26
       Notes                  : (multiple lines)

8.3.3  Temp. Sensor Model     : MET4A
       Manufacturer           : PAROSCIENTIFIC, INC
       Serial Number          : 106565
       Data Sampling Interval : 300 sec
       Accuracy               : 0.2 deg C
       Aspiration             : FAN
       Height Diff to Ant     : 0 m
       Calibration date       : 2008-06-20
       Effective Dates        : 2008-06-26/CCYY-MM-DD
       Notes                  : (multiple lines)

8.3.x  Temp. Sensor Model     : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.4.x  Water Vapor Radiometer : 
       Manufacturer           : 
       Serial Number          : 
       Distance to Antenna    : (m)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.5.x  Other Instrumentation  : (multiple lines)


9.   Local Ongoing Conditions Possibly Affecting Computed Position

9.1.x  Radio Interferences    : (TV/CELL PHONE ANTENNA/RADAR/etc)
       Observed Degradations  : (SN RATIO/DATA GAPS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.2.x  Multipath Sources      : (METAL ROOF/DOME/VLBI ANTENNA/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.3.x  Signal Obstructions    : (TREES/BUILDINGS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)


10.  Local Episodic Effects Possibly Affecting Data Quality

10.1  Date                    : 2000-04-01/2000-10-06
      Event                   : GPS Antenna malfunction (TRACKED FEW GPSSAT.)

10.2  Date                    : 2005-12-30/2006-02-10
      Event                   : Due to heavy snowfall in the region theantenna
                              : was covered by snow

10.x  Date                    : (CCYY-MM-DD/CCYY-MM-DD)
      Event                   : (TREE CLEARING/CONSTRUCTION/etc)


11.  On-Site, Point of Contact Agency Information

     Agency                   : University of Warmia and Mazury in Olsztyn
                              : Space Radio-Diagnostics Research Centre
     Preferred Abbreviation   : UWM
     Mailing Address          : Prawocheńskiego Street 9
                              : 10-719 Olsztyn
                              : Poland
     Primary Contact
       Contact Name           : Space Radio-Diagnostics Research Centre
       Telephone (primary)    : +48 89 524 55 42
       Telephone (secondary)  : +48 89 514 16 84
       Fax                    : 
       E-mail                 : lamk@uwm.edu.pl
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : (multiple lines)




12.  Responsible Agency (if different from 11.)

     Agency                   : (multiple lines)
     Preferred Abbreviation   : (A10)
     Mailing Address          : (multiple lines)
     Primary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : (multiple lines)


13.  More Information

     Primary Data Center      : BEV
     Secondary Data Center    : BKG
     URL for More Information : http://www.epncb.oma.be/_networkdata/siteinfo4on
     Hardcopy on File
       Site Map               : (Y or URL)
       Site Diagram           : X
       Horizon Mask           : X
       Monument Description   : X
       Site Pictures          : 1
     Additional Information   : (multiple lines)
     Antenna Graphics with Dimensions

LEIAR20