TUBO00CZE Site Information Form (site log v2.0)
     International GNSS Service
     See Instructions at:
       https://files.igs.org/pub/station/general/sitelog_instr_v2.0.txt


0.   Form

     Prepared by (full name)  : GOP operation center (gop_oc@pecny.cz)
     Date Prepared            : 2024-08-29
     Report Type              : UPDATE
     If Update:
      Previous Site Log       : tubo00cze_20220502.log
      Modified/Added Sections : 11


1.   Site Identification of the GNSS Monument

     Site Name                : Technical University Brno
     Nine Character ID        : TUBO00CZE
     Monument Inscription     : 
     IERS DOMES Number        : 11503M001
     CDP Number               : (A4)
     Monument Description     : PILLAR
       Height of the Monument : 3.29 m
       Monument Foundation    : ROOF
       Foundation Depth       : 3.0 m
     Marker Description       : STEEL SCREW
     Date Installed           : 1994-04-27T00:00Z
     Geologic Characteristic  : LOESS
       Bedrock Type           : SEDIMENTARY
       Bedrock Condition      : WEATHERED
       Fracture Spacing       : over 200 cm
       Fault zones nearby     : NO
         Distance/activity    : (multiple lines)
     Additional Information   : Massive concrete pillar, embedded in
                              : the bearing wall, is 3.29 m above the roof,
                              : the height of the building (above the ground)
                              : is 25.71 m, foundation depth of the building
                              : is 3 m. Point in 29.00 m above ground.
                              : Weathered bedrock is approximately 5 m under
                              : ground.


2.   Site Location Information

     City or Town             : Brno
     State or Province        : Moravia
     Country or Region        : CZE
     Tectonic Plate           : EURASIAN
     Approximate Position (ITRF)
       X coordinate (m)       : 4001470.400
       Y coordinate (m)       : 1192345.500
       Z coordinate (m)       : 4805795.600
       Latitude (N is +)      : +491221.22
       Longitude (E is +)     : +0163534.22
       Elevation (m,ellips.)  : 324.4
     Additional Information   : ITRF93, epoch 2001.5


3.   GNSS Receiver Information

3.1  Receiver Type            : TRIMBLE 4700
     Satellite System         : GPS
     Serial Number            : 20128
     Firmware Version         : 1.30/0.00
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2001-06-14T13:33Z
     Date Removed             : 2005-12-15T09:21Z
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : full serial number is 0220220128

3.2  Receiver Type            : LEICA GRX1200PRO
     Satellite System         : GPS
     Serial Number            : 457133
     Firmware Version         : 2.14/2.121
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2005-12-15T13:32Z
     Date Removed             : 2006-02-02T15:00Z
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : (multiple lines)

3.3  Receiver Type            : LEICA GRX1200PRO
     Satellite System         : GPS
     Serial Number            : 457133
     Firmware Version         : 3.00/2.121
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2006-02-02T16:00Z
     Date Removed             : 2010-08-31T10:00Z
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : (multiple lines)

3.4  Receiver Type            : LEICA GRX1200PRO
     Satellite System         : GPS
     Serial Number            : 457133
     Firmware Version         : 8.00/2.125
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2010-08-31T10:01Z
     Date Removed             : 2011-12-12T09:50Z
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : (multiple lines)

3.5  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 496604
     Firmware Version         : 8.20/4.007
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2011-12-12T11:14Z
     Date Removed             : 2011-12-20T09:50Z
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : (multiple lines)

3.6  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 457133
     Firmware Version         : 8.50/4.007
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2011-12-20T10:04Z
     Date Removed             : 2012-04-05T17:50Z
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : (multiple lines)

3.7  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 457133
     Firmware Version         : 8.51/6.110
     Elevation Cutoff Setting : 5 deg
     Date Installed           : 2012-04-05T18:10Z
     Date Removed             : 2016-03-08T09:35Z
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : (multiple lines)

3.8  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 457133
     Firmware Version         : 8.51/6.110
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2016-03-08T09:35Z
     Date Removed             : 2016-04-07T12:00Z
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : (multiple lines)

3.9  Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO
     Serial Number            : 457133
     Firmware Version         : 9.20/6.404
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2016-04-07T12:00Z
     Date Removed             : 2018-08-10T08:22Z
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : (multiple lines)

3.10 Receiver Type            : LEICA GRX1200+GNSS
     Satellite System         : GPS+GLO+GAL
     Serial Number            : 457133
     Firmware Version         : 9.20/6.405
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2018-08-10T09:18Z
     Date Removed             : 2019-04-17T07:26Z
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : BDS data is only in LB2 real-time stream (mount
                              : TUBO2).

3.11 Receiver Type            : LEICA GR30
     Satellite System         : GPS+GLO+GAL+BDS+QZSS+SBAS
     Serial Number            : 1706651
     Firmware Version         : 4.31/7.403
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2019-04-17T07:37Z
     Date Removed             : 2022-05-02T09:37Z
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : (multiple lines)

3.12 Receiver Type            : LEICA GR30
     Satellite System         : GPS+GLO+GAL+BDS+QZSS+SBAS
     Serial Number            : 1706651
     Firmware Version         : 4.52/7.111
     Elevation Cutoff Setting : 0 deg
     Date Installed           : 2022-05-02T09:43Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Temperature Stabiliz.    : 20.0 +/- 4.0
     Additional Information   : (multiple lines)

3.x  Receiver Type            : (A20, from rcvr_ant.tab; see instructions)
     Satellite System         : (GPS+GLO+GAL+BDS+QZSS+IRNSS+SBAS)
     Serial Number            : (A20, but note the first A5 is used in SINEX)
     Firmware Version         : (A11)
     Elevation Cutoff Setting : (deg)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Temperature Stabiliz.    : (none or tolerance in degrees C)
     Additional Information   : (multiple lines)


4.   GNSS Antenna Information

4.1  Antenna Type             : TRM29659.00     NONE
     Serial Number            : 29909
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.3107
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : NONE
     Radome Serial Number     : 
     Antenna Cable Type       : TRIMBLE PN 14551-00
     Antenna Cable Length     : 30 m
     Date Installed           : 2001-06-14T13:33Z
     Date Removed             : 2005-12-15T09:21Z
     Additional Information   : full serial number is 0220229909

4.2  Antenna Type             : LEIAT504        LEIS
     Serial Number            : 102923
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.3107
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : LEIS
     Radome Serial Number     : 102923
     Antenna Cable Type       : SEMIRIGID RG218
     Antenna Cable Length     : 30 m
     Date Installed           : 2005-12-15T13:32Z
     Date Removed             : 2011-12-12T09:50Z
     Additional Information   : antenna is absolute calibrated by Geo++ GmbH
                              : on May 6, 2005

4.3  Antenna Type             : LEIAR25.R4      LEIT
     Serial Number            : 10401005
     Antenna Reference Point  : BPA
     Marker->ARP Up Ecc. (m)  :   0.3113
     Marker->ARP North Ecc(m) :   0.0000
     Marker->ARP East Ecc(m)  :   0.0000
     Alignment from True N    : 0 deg
     Antenna Radome Type      : LEIT
     Radome Serial Number     : 10401005
     Antenna Cable Type       : SEMIRIGID RG218
     Antenna Cable Length     : 30 m
     Date Installed           : 2011-12-12T11:14Z
     Date Removed             : CCYY-MM-DDThh:mmZ
     Additional Information   : Antenna is absolute calibrated by Geo++ GmbH
                              : on Mar 4, 2011. Shortened serial number (401005)
                              : replaced by full serial number on
                              : 2012-03-21.

4.x  Antenna Type             : (A20, from rcvr_ant.tab; see instructions)
     Serial Number            : (A*, but note the first A5 is used in SINEX)
     Antenna Reference Point  : (BPA/BCR/XXX from "antenna.gra"; see instr.)
     Marker->ARP Up Ecc. (m)  : (F8.4)
     Marker->ARP North Ecc(m) : (F8.4)
     Marker->ARP East Ecc(m)  : (F8.4)
     Alignment from True N    : (deg; + is clockwise/east)
     Antenna Radome Type      : (A4 from rcvr_ant.tab; see instructions)
     Radome Serial Number     : 
     Antenna Cable Type       : (vendor & type number)
     Antenna Cable Length     : (m)
     Date Installed           : (CCYY-MM-DDThh:mmZ)
     Date Removed             : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


5.   Surveyed Local Ties

5.x  Tied Marker Name         : 
     Tied Marker Usage        : (SLR/VLBI/LOCAL CONTROL/FOOTPRINT/etc)
     Tied Marker CDP Number   : (A4)
     Tied Marker DOMES Number : (A9)
     Differential Components from GNSS Marker to the tied monument (ITRS)
       dx (m)                 : (m)
       dy (m)                 : (m)
       dz (m)                 : (m)
     Accuracy (mm)            : (mm)
     Survey method            : (GPS CAMPAIGN/TRILATERATION/TRIANGULATION/etc)
     Date Measured            : (CCYY-MM-DDThh:mmZ)
     Additional Information   : (multiple lines)


6.   Frequency Standard

6.1  Standard Type            : INTERNAL
       Input Frequency        : (if external)
       Effective Dates        : 2001-06-14/CCYY-MM-DD
       Notes                  : (multiple lines)

6.x  Standard Type            : (INTERNAL or EXTERNAL H-MASER/CESIUM/etc)
       Input Frequency        : (if external)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


7.   Collocation Information

7.x  Instrumentation Type     : (GPS/GLONASS/DORIS/PRARE/SLR/VLBI/TIME/etc)
       Status                 : (PERMANENT/MOBILE)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)


8.   Meteorological Instrumentation

8.1.1  Humidity Sensor Model  : HG421.65
       Manufacturer           : COMET SYSTEM, CZ
       Serial Number          : 01430040
       Data Sampling Interval :    60 sec
       Accuracy (% rel h)     : 2 % rel h
       Aspiration             : UNASPIRATED
       Height Diff to Ant     : -1.16 m
       Calibration date       : 2017-08-03
       Effective Dates        : 2001-08-28/CCYY-MM-DD
       Notes                  : Sensor is 1.16 m under GPS antenna.
                              : First calibration 2001-08-08

8.1.x  Humidity Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy (% rel h)     : (% rel h)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.2.1  Pressure Sensor Model  : TMAG 518 N4F
       Manufacturer           : CRESSTO, CZ
       Serial Number          : 1119/01
       Data Sampling Interval :  60 sec
       Accuracy               : 0.2 hPa
       Height Diff to Ant     : -1.13 m
       Calibration date       : 2017-08-03
       Effective Dates        : 2001-08-28/CCYY-MM-DD
       Notes                  : Sensor is 1.13 m under GPS antenna.
                              : First calibration 2001-07-26

8.2.x  Pressure Sensor Model  : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (hPa)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.3.1  Temp. Sensor Model     : NS520-120A
       Manufacturer           : COMET SYSTEM, CZ
       Serial Number          : 01360007
       Data Sampling Interval : 60 sec
       Accuracy               : 0.4 deg C
       Aspiration             : NATURAL
       Height Diff to Ant     : -1.17 m
       Calibration date       : 2005-12-15
       Effective Dates        : 2001-08-28/2006-02-02
       Notes                  : Sensor is 1.17 m under GPS antenna.
                              : First calibration 2001-08-08

8.3.2  Temp. Sensor Model     : NS520-120A
       Manufacturer           : COMET SYSTEM, CZ
       Serial Number          : 02360003
       Data Sampling Interval : 60 sec
       Accuracy               : 0.4 deg C
       Aspiration             : NATURAL
       Height Diff to Ant     : -1.17 m
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : 2006-02-02/2008-04-04
       Notes                  : Sensor is 1.17 m under GPS antenna.

8.3.3  Temp. Sensor Model     : NS520-120A
       Manufacturer           : COMET SYSTEM, CZ
       Serial Number          : 01360007
       Data Sampling Interval : 60 sec
       Accuracy               : 0.4 deg C
       Aspiration             : NATURAL
       Height Diff to Ant     : -1.17 m
       Calibration date       : 2017-08-03
       Effective Dates        : 2008-04-04/CCYY-MM-DD
       Notes                  : Sensor is 1.17 m under GPS antenna.
                              : Repaired sensor from 8.3.1

8.3.x  Temp. Sensor Model     : 
       Manufacturer           : 
       Serial Number          : 
       Data Sampling Interval : (sec)
       Accuracy               : (deg C)
       Aspiration             : (UNASPIRATED/NATURAL/FAN/etc)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.4.x  Water Vapor Radiometer : 
       Manufacturer           : 
       Serial Number          : 
       Distance to Antenna    : (m)
       Height Diff to Ant     : (m)
       Calibration date       : (CCYY-MM-DD)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Notes                  : (multiple lines)

8.5.1  Other Instrumentation  : rain gauge

8.5.x  Other Instrumentation  : (multiple lines)


9.   Local Ongoing Conditions Possibly Affecting Computed Position

9.1.1  Radio Interferences    : WiFi/GSM source near antenna
       Observed Degradations  : Decreasing number of observations
       Effective Dates        : 2014-08-01/2014-08-31
       Additional Information : (multiple lines)

9.1.x  Radio Interferences    : (TV/CELL PHONE ANTENNA/RADAR/etc)
       Observed Degradations  : (SN RATIO/DATA GAPS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.2.x  Multipath Sources      : (METAL ROOF/DOME/VLBI ANTENNA/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)

9.3.1  Signal Obstructions    : ROOF IN NORTH-WEST DIRECTION
       Effective Dates        : 2001-06-14/CCYY-MM-DD
       Additional Information : maximal elevation angle of the roof is
                              : 13 degrees

9.3.x  Signal Obstructions    : (TREES/BUILDINGS/etc)
       Effective Dates        : (CCYY-MM-DD/CCYY-MM-DD)
       Additional Information : (multiple lines)


10.  Local Episodic Effects Possibly Affecting Data Quality

10.x  Date                    : (CCYY-MM-DD/CCYY-MM-DD)
      Event                   : (TREE CLEARING/CONSTRUCTION/etc)


11.  On-Site, Point of Contact Agency Information

     Agency                   : Brno University of Technology
                              : Faculty of Civil Engineering
                              : Department of Geodesy
     Preferred Abbreviation   : VUT BRNO
     Mailing Address          : Veverí 95 / 60200
                              : 60200 Brno
                              : Czechia
     Primary Contact
       Contact Name           : GOP operation center
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : gop_oc@pecny.cz
     Secondary Contact
       Contact Name           : Dr. Jiri Bures
       Telephone (primary)    : +420 541 147 212
       Telephone (secondary)  : +420 541 147 136
       Fax                    : +420 541 147 218
       E-mail                 : bures.j@fce.vutbr.cz
     Additional Information   : (multiple lines)


12.  Responsible Agency (if different from 11.)

     Agency                   : Research Institute of Geodesy, Topography and
                              : Cartography
                              : Geodetic Observatory Pecny
     Preferred Abbreviation   : RIGTC GOP
     Mailing Address          : Pecny 244
                              : CZ-25165 Ondrejov
                              : Czechia
     Primary Contact
       Contact Name           : GOP operation center
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : gop_oc@pecny.cz
     Secondary Contact
       Contact Name           : 
       Telephone (primary)    : 
       Telephone (secondary)  : 
       Fax                    : 
       E-mail                 : 
     Additional Information   : Mail jakub.kostelecky@pecny.cz for Jakub
                              : Kostelecky is also valid.


13.  More Information

     Primary Data Center      : BEV
     Secondary Data Center    : BKG
     URL for More Information : http://oko.pecny.cz/vesog/stanice/tubo.html
     Hardcopy on File
       Site Map               : (Y or URL)
       Site Diagram           : (Y or URL)
       Horizon Mask           : (Y or URL)
       Monument Description   : (Y or URL)
       Site Pictures          : (Y or URL)
     Additional Information   : http://tubo.fce.vutbr.cz
     Antenna Graphics with Dimensions

TRM29659.00
Trimble L1/L2 Dorne Margolin element with chokerings
Model 29659.00

                       +-------+
                     /     +     \                        <-- 0.1280 L2
                    |      +      |                       <-- 0.1100 L1
  +--------------------------------------------------+    <-- 0.1020 TCR
  |                                                  |
  |                                                  |
  |                                                  |
  |                                                  |
+-+--------------------------------------------------+-+  <-- 0.0380
+-------------------+-------------+--------------------+  <-- 0.0350 BCR
                    |             |
                    |             |
                    +------x------+                       <-- 0.0 BPA=ARP

<--                      0.3810                      -->


LEIAT504        LEIS
Leica L1/L2 Dorne Margolin element with chokerings and radome
Model AT504

                       ____---____
                  __---           ---__
               __/                     \__
             _/                           \_
           _/                               \_
          /                                   \
        _/                                     \_
      _/                                         \_
     /                                             \
    |                                               |
   |                                                 |
  |                     +-------+                     |   <-- 0.1393
  |                   /     +     \                   |   <-- 0.1282 L2
 |                   |      +      |                   |  <-- 0.1093 L1
 |+------------------+-------------+------------------+|  <-- 0.1020 TCR
 ||                                                   ||
 ||                                                   ||
 ||                                                   ||
 ||                                                   ||
+-+---------------------------------------------------+-+ <-- 0.0380
+--------------------+-------------+--------------------+ <-- 0.0350 BCR
                     |             |
                     |             |
                     +------x------+                      <-- 0.0 BPA=ARP

<--                      0.3794                       -->


LEIAR25.R4      LEIT
Dorne Margolin with 3D choke ring (Revision 4) GPS: L1,L2,L5 GLONASS: L1,L2,L3
Galileo: E2-L1-E1,E5a,E5b,E6,AltBOC Compass: B1,B2,B3 L-BAND
Includes insert for enhanced L5 performance.

                       ___---___
                  __---         ---__
               __/                   \__
             _/                         \_
           _/                             \_
          /            +-------+            \             <--  0.1995
        _/            /         \            \_
       /        +---+-------------+---+        \          <--  0.1606  TCR
      |         |                     |         |
     |       |---------------------------|       |
    |     |---------------------------------|     |
    |  |---------------------------------------|  |
   |+---------------------------------------------+|
   ||                                             ||
   ||                                             ||
  +-+---------------------------------------------+-+
  +-----------------+-------------+-----------------+     <--  0.0320  BCR
                    |             |
                    |             |
                    +------x------+                       <--  0.0000  BPA=ARP
                                                              (5/8' thread
might
                                                               differ from BPA!)
  <--                    0.3802                   -->

ARP: Antenna Reference Point
L1 : L1 Phase Center                   L2 : L2 Phase Center
TCR: Top of Chokering                  BCR: Bottom of Chokering
BPA: Bottom of Preamplifier

Antenna heights:


                        ___---___
                   __---         ---__
                __/                   \__
              _/                         \_
            _/                             \_
           /            +-------+            \             <--  0.5108
         _/            /         \            \_
        /        +---+-------------+---+        \          <--  0.4719  TCR
       |         |                     |         |
      |       |---------------------------|       |
     |     |---------------------------------|     |
     |  |---------------------------------------|  |
    |+---------------------------------------------+|
    ||                                             ||
    ||                                             ||
   +-+---------------------------------------------+-+
   +-----------------+-------------+-----------------+     <--  0.3433  BCR
                     |             |
                     |             |
                     +------x------+                       <--  0.3113  BPA=ARP
                         ++---++
                          |   |
                          |   |
                         ++---++
                         |     |
                         |     |
                         |     |
                 +-------+     +-------+
            +----+----------x----------+----+             <-- 0.0 reference
            |                               |                     point TUBO
            |            pillar             |
            |                               |
            |                               |